Press Line Comprising of Assets Listed Below

Quantity:
1
Location:
4 Jeanes Street, Beverley SA 5009, Australia

To bid on this item you must submit a written offer.

Please login or click here to submit your offer via e-mail

For more information, click here to view details of the Sale.

Description

  • 1000 - 600 Tonne Press, D/A INR Bliss Model: DE4-1000-600-144-84-M, Year of Manufacture: 1971
    • Shut Hgt Min : 1211
    • Press Tables
      • Max : 1821
      • Bottom L - R / F - B : 3656 x 2132
      • Top L - R / F - B : 3200 x 1676
    • Length of Stroke : 991
    • Slide Adjustment : 610
    • Tool Shut Height : CONSULT ENG'G
    • Air Cush Strk : 305
    • Air Cush Ton : 136
    • Max Coil Width : NA
    • Max Coil Feed : NA
    • Coil Feed Height : NA
    • Max Coil Thick : NA
    • Strks per min : 11.4
  • 1000 - 600 Tonne Press, D/A OTR Bliss, Year of Manufacture: 1971
    • Shut Hgt Min : 957
    • Press Tables
      • Max : 1567
      • Bottom L - R / F - B : 3656 x 2132
      • Top L - R / F - B : 3656 x 2132
    • Length of Stroke : 838
    • Slide Adjustment : 610
    • Tool Shut Height : CONSULT ENG'G
    • Air Cush Strk : AS ABOVE
    • Air Cush Ton :
    • Max Coil Width :
    • Max Coil Feed :
    • Coil Feed Height :
    • Max Coil Thick :
    • Strks per min :
  • 600 Tonne Press, BLISS Model: SE4-600-144-84, Year of Manufacture: 1971
    • Shut Hgt Min : 410
    • Press Tables
      • Max : 1020
      • Bottom L - R / F - B : 3656 x 2132
      • Top L - R / F - B : 3656 x 2132
    • Length of Stroke : 610
    • Slide Adjustment : 610
    • Tool Shut Height : 1000
    • Air Cush Strk : 305
    • Air Cush Ton : 90
    • Max Coil Width : NA
    • Max Coil Feed : NA
    • Coil Feed Height : NA
    • Max Coil Thick : NA
    • Strks per min : 16
  • 600 Tonne Press, BLISS Model: SE4-600-144-84, Year of Manufacture: 1971
    • Shut Hgt Min : 410
    • Press Tables
      • Max : 1020
      • Bottom L - R / F - B : 3656 x 2132
      • Top L - R / F - B : 3656 x 2132
    • Length of Stroke : 610
    • Slide Adjustment : 610
    • Tool Shut Height : 1000
    • Air Cush Strk : 305
    • Air Cush Ton : 90
    • Max Coil Width : NA
    • Max Coil Feed : NA
    • Coil Feed Height : NA
    • Max Coil Thick : NA
    • Strks per min : 16
  • Blank Stacker / Unloader Olofstrom Volvo Model: 150-2000-2800, Year of Manufacture: 1991
  • Blank Washer Schleifelbaum Stienmetz Model: WEB28/ 4 Stg., Year of Manufacture: 1991
  • Centralising Table Olofstrom Volvo Model: 180-2019-2800, Year of Manufacture: 1991
  • Doppin Loader Olofstrom Volvo Model: 100-SM4-2300-400-310, Year of Manufacture: 1991
  • Robot Transfer KUKA 5 off Model: KCR2 / KR120-2 P2000 , Year of Manufacture: 2007
  • Scrap Conveyor System
  • Press Crown
  • Critical Spare Parts
  • From working Environment
  • Technical Drawings Available on Request

 

 

Automotive Parts Manufacturer Onsite Clearance - Part 1 - Presses, Feeder/Uncoilers and Weld Cells

Under instructions from Precision Components Australia Pty Ltd

Auction Closes: Friday, 21st September 2018 at 2:00 PM

Inspection: Wednesday 29th September 2018 from 10:00 AM to 12:00 PM or By Appointment

Location: 4 Jeanes Street, Beverley SA 5009

Contact: Andrew Monks on 0414 340 399 andrewm@evansclarke.com.au

Please Note the Following Auction Specific Terms - By registering for this auction you acknowledge these, and all other terms of sale as specified. 

Collection: By Appointment as arranged with Evans Clarke National post closure of auction - Collections to be finalised by Nov 31st 2018.

Payment: All assets must be paid for in full prior to any work commencing onsite.

Asset Removal: It is the purchasers responsibility to remove all purchased lots from site. This includes all asset preparation for transport.

Tradespeople and Contractors: All (e.g. electricians, plumbers, riggers, equipment operators) must produce relevant licences and/or white card prior to the commencement of any work on site.

Tooling, Plant & Equipment: Any equipment used onsite in the removal of purchased items must be tested & tagged, and/or compliant with OHW&S legislation and requirements,

Onsite Work: All work carried out onsite must be compliant with all OHW&S legislation, appropriate PPE must be utilised as required or specified.

Site Access: All site attendees must comply with directions given by the Vendor or Auction Staff

 



[97118+10]

This item has been viewed 120 times

 Auction Description

Automotive Parts Manufacturer Major Onsite Clearance - EOI Presses, Feeder/Uncoilers, Weld Cells, Robots, Plant & Equipment

Under instructions from Precision Components Australia Pty Ltd

EOI Closes: Thursday 31st January 2019, unless sold prior

To submit an offer email Precision@biddingonline.com.au with the specified lot number.

Inspection:  By Appointment

Location: 4 Jeanes Street, Beverley SA 5009

Contact: Andrew Monks on 0414 340 399 Precision@biddingonline.com.au

Please Note the Following Sale Specific Terms - By registering for this EOI, and/or submitting an offer, you acknowledge these, and all other terms of sale as specified. 

Collection: By Appointment as arranged with Evans Clarke National post closure of auction.

Payment: All assets must be paid for in full prior to any work commencing onsite.

Asset Removal: It is the purchasers responsibility to remove all purchased lots from site. This includes all asset preparation for transport.

Tradespeople and Contractors: All (e.g. electricians, plumbers, riggers, equipment operators) must produce relevant licences and/or white card prior to the commencement of any work on site.

Tooling, Plant & Equipment: Any equipment used onsite in the removal of purchased items must be tested & tagged, and/or compliant with OHW&S legislation and requirements,

Onsite Work: All work carried out onsite must be compliant with all OHW&S legislation, appropriate PPE must be utilised as required or specified.

Site Access: All site attendees must comply with directions given by the Vendor or Auction Staff

Environmental Compliance: All removal, disassembly of assets and work conducted onsite must be compliant with the Environmental Protection Act 1993